APPLAST

APPLASTAPPLASTAPPLAST

APPLAST

APPLASTAPPLASTAPPLAST
  • Home
  • Menu
    • Product
    • Compounding
    • Release
    • Work With Us
    • Downloads

Rubber wire and cable compound

Locomotive Wire and Cable Compound

Locomotive Wire and Cable Compound

Locomotive Wire and Cable Compound

Locomotive Wire extrution

  • EU standard locomotive cable insulation APPLAST® IR102FR
  • EU standard locomotive cable sheath APPLAST®JR104 FR
  • GE locomotive ver. F cable APPREN® IR 201FR
  • GE locomotive ver. F cable APPREN® IR 202 FR
  • New US Standard Locomotive Cable APPLAST® IR 103 FR
  • APPREN® JC 295 FR
  • APPREN® IC 193 FR
  • China Rail standard jacket APPREN® JC 290 (903# oil resist. with low Vol. Swell)
  • China Rail Maglev insulation APPREN® IC 190
  • China Rail Maglev external shielding APPREN® SCW 103 extra low in surf. R

Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Mining Cable Compound

Locomotive Wire and Cable Compound

Locomotive Wire and Cable Compound

HFFR Mining Cable

  • Mining Inner shield APPREN® SCN101
  • Mining Ext. shield APPREN® SCW101
  • Mining cable insulation APPREN® IC 185
  • Flame retardant mineral cable sheath APPREN® JC 253 FR
  • APPREN® SCN 102 inner shield bedding
  • Flame retardant insulation APPREN® IC 173 FR 
  • 5GM5 Sheath APPREN®JC283FR (-40°C)
  • Orange Sheath JC 275 FR 5GM5 
  • APPREN® JC 298 FR LSHF sheath (extra high 902# oil resist.)
  • JC300FR HFFR a bit high Shore A Low Cost
  • JC300 Yellow/Red FR HFFR a bit high Shore A Low Cost

 Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Wind Cable Compound

Locomotive Wire and Cable Compound

Household & Appliance

UL Wind Energy Cable Medium Voltage

  •   90°C wind power insulation APPREN® IC 196 
  • 90°C wind power sheath APPREN® JC 297 FR 
  • Low Voltage Wind Power Insulation (extra Small Deformation after CV cabling, Soft: shore a below 70) 
  • APPREN® IC 198; 105 °C serv. temp Insulation 
  • APPREN® JC 294 FR -55 °C LSHF Sheath 
  • (Low Cost only China region ask for extruder compliance) APPREN® IC 199 
  • (Low Cost only China region ask for extruder compliance) APPREN® IC 1003 Medium Low Price Wind Power Insulation (Goldwind) 
  • (Low Cost only China region ask for extruder compliance) APPREN® JC 2003 FR Medium Low Price Wind Power Sheath (Golden Wind)
  • APPREN® JC 2002 FR -55 Degree CPE Wind Power Sheath 
  • 125°C serv. temp Irradiated Insulation APPLAST® IR 285 FR 
  • 90°C Flame Resist. B Sheath APPREN® JC 286 FR 
  • 90 °C Odorless Wind Power Sheath (Oxgen Index 30) APPREN® JC 287 FR 
  •  -45 Degree Wind Power Sheath APPREN® JC 293 FR 
  • APPREN® JC 294 FR -55 °CLSHF Sheath 
  • High Weather Resist. (increased anti-UV) APPREN® JC 284 FR 
  • Irradiated IE4/Irradiated Wind Insulation APPLAST® IR 177 Winding at -50 degrees 
  • Irradiated SE4/Irradiated Wind Sheath APPLAST® JR 282 FR Winding at -50 °C

Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Household & Appliance

Medium & High Voltage Compound

Household & Appliance

Cable Household Applicance

  •  APPREN® IR141FR irradiated SOOW insulation 
  • APPREN® JR241FR irradiated SOOW sheath 
  • H05GG Insulation/Sheathing APPREN®IC168@150°C Air Bomb
  •  IE4 APPREN® IC171 (Strength above 8, high tear resistance) 
  • IE4 APPREN® IC172 APPREN®IC179 Low Cost (China region only, ask for compliance of your extruder)
  • APPREN® IC141FR UL44 (for samples), which meets the requirements of FT4 combustion and horizontal combustion of insulated wire cores 
  • APPREN® JC 241 FR (for samples) UL44, meets FT4 combustion
  •  APPREN® IC 165 FR (Sample Specific) UL1650 
  • APPREN® JC 265 FR (cUL) (sample only) UL1650, meets FT5 combustion 
  • APPREN® IC 162 HF (for samples) UL62, halogen-free insulation
  • APPREN® JC 262 HF (for samples) UL62, halogen-free sheath 
  • Neoprene APPLAST® IR 254 FR 
  • Neoprene APPLAST® IR 268 FR@105℃ 
  • Strength greater than 10 insulation APPREN® IC180 
  • APPREN® IC 195 FR UL62 HFFR Insulation for Flexible Cable (High Water Resistance, Dielectric Stability, Flame Retardant, 92# Oil Resistant) 

Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Shipbuild

Medium & High Voltage Compound

Medium & High Voltage Compound

Shipbuilt Wire and Cable

  •  APPREN® JC 296 FR LSZH Sheathing for Marine Cables 
  • APPREN® IC 194 FR LSZH Insulation for Marine Cables 
  • LSZH Sheathing for Oil Rigs at -40 °C APPREN® JC 288 FR 
  • Flame Retardant Insulation APPREN® IC 173 FR 
  • Motor Lead Wiring, Locomotive, Shipbuilt Cable Sheathing APPREN® JC 276 FR 
  • Oil Platform BP-ORNM-2000V-535MCM Sheathing APPREN® JC 277 FR 
  • Flame Resist C# boat cable sheath APPREN® JC 260 FR 

Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Medium & High Voltage Compound

Medium & High Voltage Compound

Medium & High Voltage Compound

66 KV EPDM Cable

  • 30KVDC APPREN® IC192 150 °C ageing (105°C service temp ) 
  • MV 35KV-66KV EPM insulation APPREN® IC 153
  • 10KV EPM insulation APPREN® IC 1010 
  • SGYEP-AD medium and high voltage EPM insulation (China region only, ask for compliance of your extruder)
  • APPREN® IC 1035 35KV insulation 
  • 110KV EPM insulation APPREN® IC 1100 

Note: APPREN®; wire and cable rubber compound

           APPLAST®; Plastic Vise

Copyright © 2025 Applast Compounding Co - All Rights Reserved.

  • Product
  • Release
  • Work With Us
  • Downloads

This website uses cookies.

We use cookies to analyze website traffic and optimize your website experience. By accepting our use of cookies, your data will be aggregated with all other user data.

Accept